Starus Recovery

From RAID Failure to Data Redemption: Step-by-Step Recovery Onboard RAID 5

Data plays an important role in our lives and keeping it safe is a priority. RAID is a technology that provides reliable data storage by combining multiple disks into a single array. However, if your RAID array created on your motherboard controller encounters problems, you may lose the data stored on it.

In this article, we will tell you how to recover your data and make your storage system reliable again.

Why RAID can fail and how to prevent it

RAID provides a level of security and fault tolerance. However, even with RAID, there are a number of reasons why an array can become damaged. Let’s look at the main causes of RAID damage and how to prevent them.

  1. Hardware problems

    • Motherboard damage:
      The motherboard is the main board of your computer and its failure can lead to loss of data access. Regularly checking and replacing outdated components will help avoid this problem.
    • Disk failure:
      One of the disks in a RAID array can fail due to physical or logical problems. Regularly monitoring disk health and replacing disks at the first sign of a problem can help prevent data loss.
  2. Power failure

    • Unstable power supply:
      Power failures, power fluctuations, or power outages can cause data corruption on disks. Using the right tools, such as uninterruptible power supplies (UPS), will help ensure stable power and protect your data.
  3. User errors

    • RAID Configuration Violation:
      Unintentional deletion or reconfiguration of the RAID array by an administrator or ordinary PC user can cause data loss. It is important to be careful and double check the actions when working with the RAID controller.
  4. Incorrect disk layout

    • Disk replacement out of order:
      When replacing a disk in a RAID array, it is important to follow the correct order and configuration of the disks. Errors in this process can result in failure.
  5. Switching settings in the BIOS

    • Incorrect BIOS settings:
      Incorrect parameter changes in the BIOS, such as selecting a different operating mode for the SATA controller, can cause the RAID configuration to be lost. Before making changes to the BIOS, it is a good idea to make sure that the RAID settings will not be affected.

To prevent RAID damage, you should regularly maintain the hardware, ensure power stability, be careful when working with the RAID controller, and keep a close eye on changes to the BIOS. It is also recommended that you back up your data to external devices or the cloud so that you can restore your information in the event of a critical failure. Following these precautions will help keep your data safe and secure.

RAID drive fault tolerance level and ability to recover data in the event of a failure

The following RAID types can be created on a desktop motherboard: 0, 1, 5, and 10. The availability of RAID support on a motherboard depends on the motherboard model. Most modern desktop motherboards support RAID 0, RAID 1 and RAID 10, but RAID 5 is also available.

We covered “What is RAID and how does it keep your data safe” in more detail earlier in the article.

The ability to recover data in the event of a raid array failure depends directly on the type of raid created on your motherboard:

This table summarizes the RAID arrays created on the motherboard:
RAID Level Description Performance Fault Tolerance
RAID 0 Data is striped across disks with no redundancy. High None
RAID 1 Data is mirrored on two disks for fault tolerance. Moderate Moderate
RAID 5 Data is striped with parity for fault tolerance. Moderate Single disk failure
RAID 10 Combination of mirroring and striping for high performance and fault tolerance. High Single disk failure in each mirrored pair

We suggest that you consider RAID 5 array recovery as an example.

Preparing for RAID 5 rebuild

  1. Back up your important files.

    Before you begin rebuilding your RAID array, the most important thing to do is to ensure the security of your data. If the array is damaged but readable, you should back up all important files to another medium, such as an external hard drive or cloud storage. Then rebuild the array or replace the failed disk with a new one.
    Why is this necessary? In case of errors during the array repair process, you don’t risk the ultimate loss of information. Making a backup is your insurance.
  2. RAID Condition Assessment.

    The first step to repairing a RAID array is to understand what happened and exactly what the problem is. Let’s start by assessing the health of your RAID.
    Check the BIOS or the RAID controller utility:
    When you turn on your computer, press the appropriate key (usually Del, F2, or F12) to access the BIOS or CTRL + I to access the Intel® Rapid Storage Technology (Intel® RST) RAID controller utility. Check the status of the RAID array. If it is marked as ” Degraded ” or ” Failed “, this also indicates a problem.
    For example, in the following screenshot, you can see that disk number “5” is missing from the array and the raid has a “Failed” status.

It is important to realize that simply identifying a problem does not mean it will be solved. However, this information will help you determine more precisely what has happened to your RAID array and what actions are required to recover.

How to get your RAID 5 array back online

Replacing a failed hard disk drive

• In the AMI BIOS (American Megatrends Incorporated):

If a single disk fails, RAID status information will be displayed before the operating system boots, indicating that the array is damaged. In the example screenshot below, you can see that disk number «0» has failed and the array status is listed as “Degrated“.

To replace a failed drive with a new one, open the Intel Rapid Storage Technology menu. To do this, press Ctrl+I at boot time. Here you will see a list of all your drives and be able to identify the failed drive by its serial number.

Turn off the computer, then unplug the failed drive and plug in a working drive instead. Then restart the computer. Open the Intel RST menu and you will be prompted to repair the failed RAID by adding a new drive to rebuild the array.

To select the desired disk, highlight it and press Enter, then its status will change to “Rebuild“. A message will be displayed at the bottom stating that “Volumes with ‘Rebuild’ status will be rebuilt within the operating system“. Press ESC to exit and continue booting the operating system.

• UEFI BIOS:

UEFI BIOS is a modern technology with a graphical interface, and you can easily identify what each section is responsible for. Although there are differences in the names and layout of menu items compared to AMI BIOS, the functionality is generally similar.

To access your RAID in the UEFI bios, go to Advanced Mode and then Advanced. In this section, look for the Intel Rapid Storage Technology item, which will display information about the status of your RAID array.

Next, follow the same steps as described above for the AMI BIOS to restore.

Data recovery after executing the Reset Disk to Non-RAID command

If you accidentally select the wrong device to rebuild the array or exclude it from the raid, when the operating system reboots, the entire array will be corrupted and your data will be inaccessible. The raid status will be marked as unreadable “Failed“.

You can use Starus RAID Recovery software to recover data from a damaged array.

A universal tool that helps to recover both a damaged RAID array and the data stored on it!

This tool is compatible with various RAID types and is capable of recovering information from failed arrays and drives that were once part of the array. It analyzes the array parameters and information about the motherboard on which it was created, then rebuilds the failed array and recovers the data.

Once the program starts, it will automatically detect the array parameters and rebuild the array. The bottom of the program window will provide detailed information about your array.

If the program did not find the array after startup – check the availability of media in Windows.
You can see available media for scanning in the left part of the program window – item “Physical disks“.

If some physical disks from the array are missing from the list, you will have to go back to BIOS and exclude these disks from the raid array. Then they will become available in Windows and the program will be able to work with them and rebuild the array.

You can also switch the SATA drive mode from RAID mode to AHCI mode in the BIOS to make it available in Windows operating system.

AHCI is a modern drive mode that provides advanced functionality. It allows for hot swapping of hard disks and features a hardware command priority (NCQ) algorithm that significantly improves drive and system performance.

Before you start the data recovery process, make sure you have a drive with enough capacity to store the recoverable files.

To start recovery, right-click the partition icon and select “Quick Scan“. When the scan completes, select the necessary files or directories and click “Recover“. Then specify a location to save the recovered files and confirm the operation. When the recovery is complete, all files will be available in the specified directory.

If a quick search does not yield the results, you are looking for, you can perform a “Full Analysis“. This process will take longer, but will recover all available files, including deleted files.

How to get your data back if your motherboard or RAID controller malfunctions

Due to hardware malfunctions or motherboard failure, you may need to recover information from connected drives on another computer. However, without special programs, recovery may be difficult because the new motherboard controller will not be able to automatically detect the array parameters. In this case, the operating system may prompt you to initialize or format the drives, which will certainly delete all data from them.

It is strongly not recommended to perform this operation as it will irrevocably delete your data. However, if you have already encountered this problem, our utility will automatically repair RAID, allow you to scan disks and recover important files.

Delete Volume – restore after RAID erasure in Intel RST

Starus RAID Restore is able to recover your data even after complete RAID deletion via Intel Rapid Storage Technology menu. In this case, the program will automatically detect the type of destroyed array and recover it. Simply run a scan and recover the necessary files.

If for some reason the program was unable to repair the destroyed array automatically, you will have to do it manually using RAID Сonstructor.

Select “Manual Creation” and click “Next“. Here you will need to specify all the array parameters such as array type, block size, order, number of media and select them from the list and set the correct order. If there are any missing disks, you need to add them blank. After entering all the data, click “Add” and the array will appear in the disk manager. Then perform a scan and restore the necessary files.

The fifth RAID level remains functional even after a single media failure, but if two disks stop working, the array becomes completely inoperable and file recovery without backup media becomes difficult. With our program you can recover information even if two or more media are missing, but some data may be corrupted.

Conclusion

It is important to realize that even when a motherboard fails or a RAID array is destroyed, there are reliable data recovery tools and methods available. Our Starus RAID Recovery utility provides a reliable solution for such challenging scenarios by automatically detecting and restoring arrays or providing manual recovery options through the RAID Builder.

We remind you of the importance of regularly backing up your critical data to keep your information safe and available in case of unforeseen events.

We hope you never experience another data loss, but if you do, we are always ready to help you recover your valuable files!

Exit mobile version